mail
info@perfectchloro.com
call

+91 98403 67667

Logo
  • Home
  • Company Profile
  • Products & Services
    • Gas Chlorinators
      • Vacuum Feed Chlorinations System
      • Gravity Feed Chlorinations System
    • Evaporators
    • Chlorine Tonner Leak Detection & Absorbtion System
    • Chlorine Gas Leak Detector
    • Emergency Kit
    • Chlorine Handling, Storage, Safety, Testing & Monitoring Devices
  • Standard Items
  • Downloads
    • Completion Certificates
    • Commissioning Certificates
  • Gallery
  • Contact Us

Emergency Kit

Introduction


Chlorine has many diversified uses including water treatment and many other technical processes. However, Chlorine Gas is highly hazardous and virulent in nature. So, exceptional precaution is to be taken in areas where chlorine is stored and handled.

If Plant Personnel are exposed to even low concentrations of chlorine gas for an extended period, it poses grave health hazard. Also, chlorine corrodes costly plant machinery resulting in wastage of time and money. Chlorine leak never gets arrested by itself, it only gets worse if not properly corrected and in time.

Chlorine Emergency Kit has been designed by our experienced team of Engineers to hold back / arrest most of the leaks arising from storing and handling of a Chlorine Container.

Kit- A - Model - 1

Cylinder-Emergency Kit (A)

The potential leak areas in a Cylinder [ capacity of around 85 kgs/100 Kgs ] are

  • Leaks from Valves
  • Leaks in the Cylinder Body.

This Emergency Kit 'A' has the tools and fixtures to hold back / arrest leaks in these potential areas.

Ton Container-Emergency Kit (B)

The potential leak areas in a Ton Container [or Tonner with capacity of around 930kgs] are

  • Leaks from Valves.
  • Leaks in the Container Body.
  • Leaks from Fusible Plugs.

This Emergency Kit 'B' has the tools and fixtures to hold back/arrest leaks in these potential areas.

Easy to handle tools and fixtures enable the users to stop/handle dangerous leaks in the shortest possible time. Moreover, clear Instruction Manual is provided with each Kit, to guide the user with step by step procedures in handling these tools and fixtures in arresting/containing the leak.

This is a very simple, user-friendly life saving kit and is a must in area where Chlorine container is used.

Kit- B - Model - 1

Kit- B - Model - 2

Precaution

Please note that during gas leaks, Emergency Kits should be used by trained Personnel wearing fully working, Self Contained Air Breathing Apparatus.

Regular Mock-Drills on handling Tonner /Cylinder leaks should be provided to all Operation/Maintenance Personnel, so that everyone is well trained in handling Tonner / Cylinder Leak Emergencies.

Sailent Features

  • Simple.
  • Direct & Quick Mounting.
  • Rugged.
  • Field Tested.
  • User-friendly.
  • Versatile.
  • Economical.

Separate Emergency Kits have to be used for Chlorine Cylinders of around 85 kgs or 100 kgs and Chlorine Ton Containers of around 1000 Kgs capacity.

  • Cylinder 100 kgs Capacity - Emergency Kit 'A'.
  • Ton Container 930 kgs - Emergency Kit 'B'.

Technical Specification


S.No Name of Item Cylinder Kit A Tonner Kit B
Device 1 for Valve leaks
01 Base Bar Assembly 1 No -
02 Hood 1 No 1 No
03 Hood Vent Value 1 No 1 No
04 Hood Tightening Bolt 1 No 1 No
05 Chains 3 Nos -
06 Yoke for Chains 1 No -
07 Gasket for Hood 1 No 1 No
08 Front Bar - 1 No
09 Back Bar - 1 No
10 Tie Rods - 4 Nos
11 Tie Rod Connectors - 2 Nos
12 Saddle Chain - 2 Nos
13 Tie Rod End Nut - 1 No
Device 2 for Fusible Plug Leaks
14 Hood(small) - 1 No
15 Gasket for Small Hood - 1 No
16 Yoke for Plug - 1 No
17 Gasket for Cap Nut - 1 No
18 GStud on Yoke - 1 No
19 Cap Nut - 1 No
S.No Name of Item Cylinder Kit A Tonner Kit B
Device 3 for Body Leaks
20 Chain for Body 1 No 1 No
21 Yoke - 1 No
22 Yoke with Base for Body 1 No 1 No
23 Yoke Tightening Bolt 1 No 1 No
24 Ruber Patch for Base 3 Nos -
25 Base for Body - 1 No
Additional Items
26 Wooden Drift Pin (1 Big & 1 Small)2 Nos 2 Nos -
27 Steel Drift Pin (1 Big & 1 Small) 2 Sets 2 Sets
28 Hammer 1 No 1 No
29 Valve Cap Nut 1 No 1 No
30 Set of tools - (Spanners 10-11,30-32, ½” x 3/8” / scraper) 1 Set 1 Set
31 Spare Gasket 1 Set 1 Set
32 Flexible Copper Connector 1 No 1 No
33 Valve Yoke 1 No 1 No
34 Chlorine Cylinder Valve Key (IS : 3224) 1 No 1 No
35 Complete PVC Protective Clothing 1 Set 1 Set
36 Gas Mask Cannister type 1 No 1 No
37 Instruction Manual 1 No 1 No
38 Steel Box 1 No 1 No
Indugi

We would like to introduce ourselves as a leading Engineering Firm specializing in the field of Chlorination Systems and Accessories used in Drinking Water, Cooling Water, Waste Water Treatment and other specialized applications for more than 32 years, since 1992.

Quick Links

  • Home
  • Company Profile
  • Standard Items
  • Gallery
  • Completion Certificates
  • Commissioning Certificates
  • Contact Us

Our Services

  • Gas Chlorinators
  • Evaporators
  • Chlorine Tonner Leak Detection & Absorbtion "System
  • Chlorine Gas Leak Detector
  • Emergency Kit
  • Chlorine Handling, Storage, Safety, Testing & Monitoring Devices

Get in Touch

SP-16, Ambattur Industrial Estate,
3rd Cross Main Road, 5th Street,
Behind Old EB sub-station,
Chennai - 600 058
+91 98403 67667
+91 87545 42266
+91 98400 29244
info@perfectchloro.com sales@perfectchloro.com
Copyright © 2023 Perfect Chloro System - All Rights Reserved.
  • Privacy Policy
  • Terms & Condition